Mike's PBX Cookbook

Baystack 470 - Configuration

bay470-48.png
Nortel Baystack 470, 48T 48-Ports 10Base-T, 100Base-TX, 2 x GBIC

Introduction:

Before you can use the GUI for configuration, you must set an IP address for the switch using a DB9 cable connected to the front panel console port (9600 8-N-1).

  1. Connect a TTY (9600 8-N-1) to the switch Console port.
  2. Power-up the switch.
  3. After the Nortel logo is displayed, press CTRL-Y to display the Main Menu.
  4. Select IP Configuration/Setup and press return, or press i from the main menu.
  5. For a stand-alone switch, in the In-Band Switch IP Address field, enter the IP address of the switch..
  6. For a stack configuration, in the In-Band Stack IP Address field, enter the Stack IP address.
  7. In the Default Gateway field, specify the default gateway address.
  8. Press CTRL-C to return to the main menu.
470mmenu.png
Baystack 470 - Main Menu

You can now open the switch IP address in a web-browser, and use the GUI interface for configuration.
Note: Java Runtime Environment (JRE) is required for the left navigation menu to display correctly. bay470.png

From the left navigation menu, choose: Administration ➤ Quick Start (if available).

Configure for CS1000E:

Configure using the web-based GUI: Odd ports ELAN even ports TLAN.

1. Application ➤ Spanning Tree ➤ Port Configuration

2. Application ➤ VLAN >➤ VLAN Configuration ➤ click Create VLAN

3. Application ➤ VLAN ➤ Port Configuration

4. Application ➤ Multilink Trunk ➤ Group

5. Administration ➤ Logout ... you're finished!

If you log back in to check the status of the ports and you see that 47 and 48 have changed their PVID from 1 to 2, this is normal, it has to do with the traffic that is going across the link.

You do this on each Baystack. At step 4, if you have a remote site then you will add members for Trunk 2.

Use fiber cables for trunking (ports 47 & 48), patch cables will not pass all of the information that is needed.

(With this configuration you will not need an ELAN xover cable to connect ELAN to ELAN in the Baystacks. You would also need to connect a loop from Baystack 1 to 2, 2 to 3, and 3 to 1.)